Customization: | Available |
---|---|
Theory: | Electromagnetic Relay |
Usage: | Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. ST3P-P mechanical timer electric time delay relay Application
ST3P series time relay is used ASIC and professional manufacturing technology to produce innovative time relay, with small size, light weight, delay a wide range of anti-interference ability, long life characteristics to be suitable for a variety of demanding precision, high reliability, automation and control sites used for delay control . |
2. ST3P-P mechanical timer electric time delay relay Specifications and parameters
CLASSIFICATION |
TIMER |
||
MODEL |
ST3P |
||
DIMENSIONS |
50H*40W*57.5D |
||
MOUNTING&SOCKER |
SURFACE(-N) |
PF083A-E |
|
FLUSH(-Y) |
US-08 P3G-08 |
||
FULL TIMING RANGE |
A:0.05 - 0.5s/5s/30s/3min |
||
RATED VOLTAGE |
AC(V):24 - 220 DC(V):24 - 110(50/60Hz) |
||
INDICATOR OPERATING |
ON-UP Operating |
||
O/P CONTACT |
MODEL |
ST3PA |
ST3PC |
TIME LIMIT 1C |
- |
5A |
|
TIME LIMIT 2C |
5A |
- |
|
INSTANTENOUS 1C |
- |
5A |
|
LIFE |
MECHANICAL |
5*107 times |
|
ELECTRICAL |
10 5 times |
||
ACCURACY |
REPEA ERROR |
±2% max |
|
SETTING ERROR |
±5% max |
||
VOLTAGE ERROR |
±5% max |
||
TEMP.ERROR |
±2% max |
||
RESET TIME |
0.5 sec max |
||
CONSUMED POWER |
2VA |
||
AMBIENT TEMPERATURE |
-10ºC~+55ºC |
||
AMBENT HUMINITY |
35~85%RH |
||
WEIGHT |
100g |
3. ST3P-P mechanical timer electric time delay relay Other St3p series time relay Specifications and parameters
Model |
Action in the form of |
Contacts |
Delay range |
Rated voltage (Us) |
ST3PA |
Power delay |
Delay2Change |
A:0.05-0.5s/5s/30s/3min B:0.1-1s/10s/60s/6min C:0.5-5s/50s/5min/30min D:1-10s/100s/10min/60min E:5-60s/10min/60min/6h F:0.25-2min/20min/2h/12h G:0.5-4min/40min/4h/24h |
AC24, 110,220 V 50/60Hz DC24, 48,110 V |
ST3PG |
Interval delay |
Delay2Change |
||
ST3PC |
Instantaneous type(Interval delay) |
Delay1Instantaneous conversion1Change |
||
ST3PF ST3PF-2 |
Off delay |
Delay1Conversion or delay2Change |
0.1-1s 0.2-2s 0.5-5s 1-10s 2.5-30s 5-60s |
AC110, 220V 50/60Hz DC24, 48,110 V |
ST3PK |
Off-Delay |
Delay1Change |
0.1-1s 0.25-2s 0.5-5s 1-10s 2.5-30s 5-60s 15-180s |
AC110V/220V 50/60Hz DC24V |
ST3PY |
Star-Delta start-up delay |
Instantaneous delay delta converter1Normally open |
1-10s 2.5-30s 5-60s |
AC110/220V 50/60Hz |
ST3PR |
Reciprocating cycle delay |
Delay1Change |
0.5-6s/60s 1-10s/10min 2.5-30s/30min |
AC110/220V 50/60Hz DC24, 48V |
4. ST3P-P mechanical timer electric time delay relay Normal operating conditions and installation conditions:
4.1 The use of the environment: the sea disturbance height of not more than 2000 meters, ambient temperature is not higher than +40 and no less than -5 ; supply voltage range of 85% -110% rated voltage; in the absence of a serious shock and explosion hazard medium, and medium, non-corrosive metal and undermine the insulation is sufficient gas and dust; in less rain and snow hit areas. 4.2 vertical or horizontal installation. Technical features 1, supply voltage: AC (50Hz) 24V, 36V, 110V, 127V, 220V, 380V; DC: 24V (other voltages can be customized); 2, electrical life: ≥ 10 × 104 times; 3, Mechanical life: ≥ 100 × 104 times; 4, contact capacity: AC220V 3A; DC220V 0.5A COSφ = 1; 5, use the Class: AC-15 DC-13; 6, repeated the error: "1%; 7, reset time: ≤ 1 sec; 8, power consumption: ≤ 1.5W (DH11S ≤ 3W). |